1.De ambientair temperatueren is net heger as +40 ℃ net leger as -40 ℃;
2.De hichte boppe seenivo doasis net mear as 1000-2000m (de plateau ares moatte wurde oanjûn by it bestellen);
3.AC systen frekwinsje is 50Hz of 60Hz
4.De krêftfrekwinsjespanning dy't foar in lange tiid oan 'e arrester tapast wurdt, is net mear as de trochgeande wurkspanning fan' e arrester
5.Maksimum wyn snelheid net boppe 35m / s
6.De ierdbevingintensiteit is net mear as 7 graden;
7.De smoarge gebieten moatte wêze givende yndikaasje.
Kontakt mei ús opnimme
1. De ambient lucht temperatueren is net heger as +40 ℃, net leger as -40 ℃;
2. De hichte boppe seenivo doasis net mear as 1000-2000m (de plateau ares moatte wurde oanjûn by it bestellen);
3. AC systen frekwinsje is 50Hz of 60Hz;
4. De krêftfrekwinsjespanning dy't foar in lange tiid oan 'e arrester tapast wurdt, is net mear as de trochgeande wurkspanning fan' e arrester;
5. Maksimum wyn snelheid net boppe 35m / s;
6. De ierdbevingintensiteit is net mear as 7 graden;
7. It smoarge gebiet moat dúdlik oantsjut wurde.
De sinkokside arrester wurdt tapast te beskermjen de elektryske equimpent yn AC macht systeem tsjin de skea resultearre út atmosfearyske over-voltage en operasjonele over-voltage.
De technyske prestaasjes fan it produkt befêstiget GB11032-2000, IEC60099-4, IEEE.C62.11 standert technyske easken.
Type | System Rated spanning KV(rms) | Arrester Rated spanning KV(rms) | Kontinu Rated voltage KV(rms) | DC1mA spanning (kv) | Wjerljocht Impuls oerbleaune spanning (kv) | Steile weach Impuls oerbleaune spanning (kv) | 2ms fjouwerkant wave Impuls aktueel tsjinhâlde (IN) |
HYWS -3.8/17 | 3 | 3.8 | 2.4 | 7.5 | 17 | 19.6 | 100 |
HYWS -7.6/30 | 6 | 7.6 | 4 | 15 | 30 | 34.5 | 100 |
HYWS -12.7/50 | 10 | 12.7 | 6.6 | 26 | 50 | 57,5 | 150 |
HYWS17/50 | 10 | 17 | 13.6 | 26.5 | 50 | 57,5 | 150 |
HYWZ-7.6/27 | 6 | 7.6 | 4 | 14.5 | 27 | 31 | 200 |
HYWZ-12.7/45 | 10 | 12.7 | 6.6 | 24 | 45 | 51.8 | 200 |
HYWZ-17/45 | 10 | 17 | 12.7 | 24 | 45 | 51.8 | 200 |
HYWZ-42/134 | 35 | 52 | 40.8 | 78 | 134 | 154 | 400 |
HY2.5WD-7.6/19 | 605 | 7.6 | 4.8 | 11.5 | 19 | 21.9 | 200, 400 |
HY2.5WD-12.7/31 | 10.5 | 12.7 | 6.6 | 19 | 31 | 35.7 | 200, 400 |
HY2.5WD-16.7/40 | 13.8 | 16.7 | 9 | 25 | 40 | 46 | 400 |
HY2.5WD-19/45 | 15.7 | 19 | 10 | 28.5 | 45 | 51.8 | 400 |
HY5WR-7.6/27 | 6 | 7.6 | 4.8 | 13.8 | 27 | 20.8 | 400 |
HY5WR-12.7/45 | 10 | 12.7 | 6.6 | 23 | 45 | 35 | 400 |
HY5WR-42/134 | 35 | 52 | 23.4 | 73 | 134 | 105 | 400 |
Nim HY5WS-17/50 as foarbyld: H-Compound jas yn organisme ;Y-Metalen okside bliksem arrester; 5-It mark ropt om yn te skeakeljen
elektrisiteit de elektryske stroom(KV);W-DeW betsjut gjin spleet te hawwen, de C betsjut om de spleet te fêstigjen; S-De S betsjut om tegearre te gean
mei de elektrisiteit; Z elektrisiteit stands; D elektryske technyk type; R elektryske kapasiteit type 17-It foarkommen fan de tongersom regelet de elektryske spanning (KV) 50-
It mark ropt elektrisiteit oan te skeakeljen elektryske stroom ûnder grutste parse (KV).